Two dominant stud welding processes are used across construction, manufacturing, and fabrication: Drawn Arc (DA) and Capacitor Discharge (CD). Choosing the wrong one costs you time, money, and weld quality. Here's how to pick the right process for your job.
Drawn arc welding uses a high-current arc to melt the base of the stud and the base material simultaneously. The stud is then plunged into the molten pool, forming a full 360° fusion weld. It requires a ferrule (ceramic shield) or shielding gas to protect the weld pool.
Arc welding is used for structural applications — shear studs on bridge decks and composite beams, deformed bar anchors, and large-diameter threaded studs on heavy plate. Diameters typically range from 1/4" to 1-1/4".
CD welding discharges a bank of capacitors in milliseconds, creating an extremely fast, low-heat weld. Because the heat input is so low, it does not distort thin base materials and leaves virtually no witness mark on the reverse side. No ferrule is required.
CD is used for smaller-diameter studs on thin sheet metal, HVAC panels, electrical enclosures, insulation pins, and sign attachment. Diameters typically range from #4-40 up to 3/8".
If you're doing structural steel work, you need arc. If you're attaching to thin sheet metal or panels, you need CD. Still unsure? Use our Equipment Finder tool or call us — we'll match you to the right machine in 2 minutes.